Avaliação do Seio Maxilar: Radiografia Panorâmica Versus Tomografia Computadorizada de Feixe Cônico

Autores

  • Murilo Rizental Pacenko Unopar, Londrina-PR-Brasil
  • Ricardo de Lima Navarro Universidade Estadual de Maringá. PR-Brasil.
  • Thais Maria Freire Fernandes UNOPAR, Programa de Pós-Graduação Stricto Sensu em Odontologia. PR-Brasil.
  • Ana Cláudia de Castro Ferreira Conti Universidade do Sagrado Coração. SP-Brasil.
  • Fábio Domingues UNOPAR, Programa de Pós-Graduação Stricto Sensu em Odontologia. PR-Brasil.
  • Paula Vanessa Pedron Oltramari-Navarro UNOPAR, Programa de Pós-Graduação Stricto Sensu em Odontologia. PR-Brasil.

DOI:

https://doi.org/10.17921/2447-8938.2017v19n3p205-208

Resumo

O objetivo deste estudo retrospectivo implica em comparar a presença de velamento, o espessamento de mucosa e a presença de septo no seio maxilar em radiografias panorâmicas e tomografias computadorizadas de feixe cônico (TCFC). A amostra foi composta por 100 pacientes do arquivo, que apresentavam as radiografias panorâmicas e as TCFC antes do início do tratamento ortodôntico, sendo 57 mulheres e 43 homens, com média de idade de 19,08 anos. Foram incluídas nesta pesquisa apenas os exames que apresentavam boa qualidade e bom posicionamento do paciente. A avaliação do velamento, espessamento de mucosa e presença de septo no seio maxilar foi realizada por um único examinador calibrado, de forma independente, nas radiografias e nas TCFC. A concordância entre os exames foi avaliada por meio do teste Kappa. Os resultados demonstraram boa concordância entre as radiografias panorâmicas e TCFC (Kappa entre 0,62 a 0,72), com -90, -88 e 89% de convergência entre os métodos, para velamento do seio maxilar; espessamento de mucosa e presença de septo no seio maxilar, respectivamente. Pode-se concluir que foi encontrada concordância satisfatória na avaliação do velamento, espessamento de mucosa e presença de septo no seio maxilar entre as radiografias panorâmica e TCFC. Dessa forma, as características do seio maxilar foram identificadas, de maneira semelhante, na radiografia panorâmica e na TCFC.

Palavras-chave: Tomografia Computadorizada por Raios X. Radiografia Panorâmica. Diagnóstico.

Abstract
The objective of this retrospective study was to compare the presence of filled maxillary sinus, mucosal thickening and the presence of septum in the maxillary sinus on panoramic radiographs and concomitant computed tomography (CBCT) scans. The sample consisted of 100 patients from the archive who presented the panoramic radiographs and the CBCT before the beginning of the orthodontic treatment, being 57 women and 43 men, with a mean age of 19.08 years. Only the exams that presented good quality and good positioning of the patient were included in this study. The evaluation of the presence of filled maxillary sinus, mucosal thickening and the presence of septum in the maxillary sinus was performed by a single examiner, regardless of who was calibrated on panoramic radiograph and CBCT. The agreement among the exams was assessed by means of Kappa test. The results showed good agreement between panoramic radiograph and CBCT (Kappa between 0.62 and 0.72), with -90, -88 and 89% convergence between the methods, for the presence of filled maxillary sinus, mucosal thickening and presence of septum in the maxillary sinus, respectively. It can be concluded that satisfactory agreement was found in the evaluation of the the presence of filled maxillary sinus, mucosal thickening and presence of septum in the maxillary sinus between the panoramic and CBCT radiographs. Thus, the characteristics of the maxillary sinus were similarly identified in panoramic radiography and CBCT.

Palavras-chave: Tomography, X-Ray Computed. Radiography, Panoramic. Diagnosis.

Downloads

Publicado

2017-09-30

Como Citar

1.
Pacenko MR, Navarro R de L, Freire Fernandes TM, de Castro Ferreira Conti AC, Domingues F, Pedron Oltramari-Navarro PV. Avaliação do Seio Maxilar: Radiografia Panorâmica Versus Tomografia Computadorizada de Feixe Cônico. J. Health Sci. [Internet]. 30º de setembro de 2017 [citado 21º de novembro de 2024];19(3):205-8. Disponível em: https://journalhealthscience.pgsscogna.com.br/JHealthSci/article/view/5198

Edição

Seção

Artigos